Spence steam pressure regulating valves on BoilerSupplies.com are the Type E main pressure regulating valve, the D series pressure reducing pilot and the Type D-50 direct-operated pressure regulating valve. The Spence bends and fittings that pipe pilot to main valve are listed beside them. Spence valves serve steam lines that need less pressure than the boiler makes. Read the tags on the main valve and the pilot: type, size and the downstream pressure they hold. Match those, or send both tags for a quote.

About Spence Steam Pressure Regulating Valves

Spence Engineering Company of Walden, New York, was founded in 1926 by Paulsen Spence, who patented the normally closed, external pilot-operated packless pressure regulator. A Spence pressure regulating valve takes steam at main pressure and holds a lower, steady pressure downstream, in building heating systems, institutions and industrial plants.

The Spence Type E main pressure regulating valve is on BoilerSupplies.com as a complete unit and as the valve only. BoilerSupplies.com also lists the Spence D series pressure reducing pilot, the Spence Type D-50 direct-operated pressure regulating valve, and Spence bends and fittings. The Type E with a D series pilot is the pilot-operated pair: the pilot senses downstream pressure and positions the main valve, which suits larger loads and a wide flow range. The Type D-50 senses pressure on its own diaphragm and suits smaller loads. The bends and fittings are the pipe pieces that run from the pilot to the main valve. Pick by the load first, pilot-operated for the large one and direct-operated for the small one, then match the pipe size.

 

Key facts

  • Spence Engineering Company was founded in 1926 by Paulsen Spence in Walden, New York.

  • Paulsen Spence held the original patent for the normally closed, external pilot-operated packless pressure regulator.

  • BoilerSupplies.com lists the Spence Type E main pressure regulating valve as a complete unit and as the valve only.

  • BoilerSupplies.com lists the Spence D series pressure reducing pilot, the Type D-50 direct-operated pressure regulating valve, and Spence bends and fittings.

  • A Type E main valve with a D series pilot is pilot-operated; the Type D-50 is direct-operated and senses pressure on its own diaphragm.

  • In-stock small-pack orders placed before 2:00 PM EST, Monday through Friday, ship the same day.

 

Is a Spence pressure regulating valve a PRV, a pressure reducing valve or a steam regulator?

All of those: pressure reducing valve, PRV, steam pressure regulator and reducing valve are names for the same Spence valve on BoilerSupplies.com. A pressure reducing station is that valve piped in with its strainer, bypass and gauges. The Type E main valve with its D series pilot is the pilot-operated type. The Type D-50 is the direct-operated type, also called a direct-acting regulator. Order by the type on the tag.

 

What do you need from me to replace a Spence main valve or pilot?

Send the two tags, one from the main valve and one from the pilot. They carry the type (Type E, D series or Type D-50), the pipe size and the downstream pressure the valve is set to hold. Add the steam pressure on the inlet side and what the line feeds. Say whether you need the complete unit, the main valve only, the pilot only, or the bends and fittings.

 

Do I order the Spence Type E main valve and the D series pilot together or separately?

Either way: BoilerSupplies.com lists the Spence Type E as a complete unit, main valve with pilot, and as the valve only, with the D series pilot on its own listing. A new installation usually takes the complete unit. A plant replacing a pilot that no longer holds pressure on a sound main valve orders the pilot alone, and new bends and fittings if the old ones are scaled or clogged.

 

What kind of load calls for the pilot-operated Spence Type E rather than the Type D-50?

A large load with a wide swing in flow: the pilot-operated pair, the Type E main valve under a D series pilot, handles that. The small pilot does the sensing and the big valve does the work. The Type D-50 senses on its own diaphragm and is the choice for a small load. Match the pipe size either way.

 

Why is my Spence regulating valve not holding downstream pressure?

On a pilot-operated Spence valve, start at the pilot. A pilot with a failed diaphragm or dirt under its seat cannot position the main valve. A main valve with a cut seat passes steam when it should be shut. Scale in the bends and fittings between pilot and main valve chokes the line the pair depends on. Check the pilot, then the main valve, then the piping between.

 

Take a picture of both tags, main valve and pilot, and send them with the quantity through BoilerSupplies.com. By phone, Boiler USA is at 1-770-957-9599, toll free 1-800-780-3776.